Slurry pumps are widely used to transport corrosive/ abrasive and high concentration slurry in many industries.
2022年3月17日星期四
AHE Slurry Pump for Mining Tailings
Slurry Pump Main part number at the drawing
No.
1 Impeller E4147EP Hi Chrome A05, A61
2 Volute Liner E4110EP Hi Chrome A05, A61
3 Thoat Bush E4083EP Hi Chrome A05, A61
4 Frame Plate Liner Lnsert E4041EP Hi Chrome A05, A61
5 Frame Plate Liner Insert Gasket E122 Rubber
6 Intake Joint E4060 Rubber
7 Discharge Joint Ring E4132XLP Rubber
8 Volute Liner Seal E4124 Rubber
9 O Ring E109 NBR Rubber
10 Impeller - O Ring F064 NBR Rubber
11 Shaft Sleeve E075 3Cr13
12 Bearing assembly EE005M
13 Frame Plate E4032 QT500
14 Cover Plate E4013 QT500
15 Bearing Housing E004M G01/HT200
16 Base E003M G01/HT200
17 Shaft E073M 45#
Pump Model : 6X4 EE -AHE
Material : Throut bush / Impeller : High chrome Alloy Cr 30% A61
Back liner / Volute : High Chrome Alloy Cr26 A05
Shaft Sleeve : D075 J04 (Ceramica Cated Shaft Sleeve)
Expeller Ring/ Expeller: High Chrome Alloy A05
Seal Type : High Seal
Motor : 4- 160kw
Drive type : DCz Drive
Supply Range : Pump, Motor, Base plate, Coupling, Guard
041: Frame Plate Liner Insert--E4041EPA61
147: Impeller --E4147EPA61
110: Volute Liner--E4110EPA61
083: Throatbush--E4083EPA61
Katherine Hou
Shijiazhuang Naipu Pump Co., Ltd
Tel: +86-311-83802338 Fax: +86-311-83809529
Cellphone/ WeChat/ WhatsApp: +86-15028111051
Skype: katherine_naipump URL: www.naipump.com
2017年8月15日星期二
450WSG 18 inches River Sand Pump for Dredging Machine
450WSG 18 inches River Sand Pump for Dredging Machine
Heavy duty sand gravel pump for river suction. Single casing pump sturcture.
1. Shaft 2. Frame 3. Impeller Disassembly Ring 4. Connecting Plate 5. Back Liner 6. Pump Body 7. Pump Cover 8. Front Liner 9. Impeller 10. Supporting Plate
![]() |
Ddredging Pump's Frame Style |
1. Gear Box 2. Impeller Disassembly Ring 3. Seal Assembly 4. Connecting Plate 5. Back Liner 6. Pump Body 7. Pump Cover 8. Front Liner 9. Impeller 10. Supporting Plate
![]() |
Dredging Pump & Gear Box Consturction Diagram |
Katherine Hou
Shijiazhuang Naipu Pump Co., Ltd
Tel: +86-311-83802338 Fax: +86-311-87162902
Cellphone/ WeChat/ WhatsApp: +86-15028111051
2017年7月24日星期一
50ZJH High Head High Chorme Alloy A05 HH Slurry Pump
50ZJH High Head High Chorme Alloy A05 HH Slurry Pump
Part Code No.: D075C21-1, D003MG01-1, D044G01-1, DAM117C21-1, DH2032D21-1, DH2013D21-1, DH2147A05-1, DH2110A05-1, DH2083A05-1, DH2041A05-1, DH078G01-1, DAM028G01-1, DAM028A05-1, DAM029G01-1, DAM029A05-1, DH2302E02-1, DH2304E02-1, D004MG01-1, DAM073ME05-1, DAM005M-1...
Katherine Hou
Shijiazhuang Naipu Pump Co., Ltd
Tel: +86-311-83802338 Fax: +86-311-87162902
Cellphone/ WeChat/ WhatsApp: +86-15028111051
2017年4月19日星期三
14/12FF-AH Heavy Duty Slurry Pump
14/12FF-AH Heavy Duty Slurry Pump
Naipu offering wet end part material as following. Metal A05, A07, A12, A33, A49, A61 and etc. Rubber R08, R26, R33, R55, S01, S21, S31, S42 and etc. Special materail: U01, EPDM, PU, CR, Hastelloy 276-C, Ferralium and etc.
Naipu is willing to undertake any OEM (Original Equipment Manufacture) order for pump and mining equipment accoring to the drawing or sample.
Katherine
Shijiazhuang Naipu Pump Co., Ltd
Tel: +86-311-83802338 Fax: +86-311-87162902
Cellphone/ WeChat/ WhatsApp: +86-15028111051
2017年3月24日星期五
The Corrosion Reason and Solution in Slurry Pump
Katherine Hou
Shijiazhuang Naipu Pump Co., Ltd
Tel: +86-311-83802338 Fax: +86-311-87162902
Cellphone/ WeChat/ WhatsApp: +86-15028111051

1. Electrochemical corrosion:
The pump flow channel using same metal materail.
Small wearing parts as an anode made of low-potential metal. Large parts as the cathode made of high-potential metal.
2. Uniform corrosion:
Using suitable material(including non-metal). Consider sufficient corrosion allowance when designing the pump.
3. Intercrystalline corrosion:
Annealing treatment for stainless steel materail part. or using ultra-low carbon stainless steel.
4. Pitting corrosion:
Using Mo steel(usually 2.5%Mo). And Mo content should be increased accordingly while Cl content and temperature rise.
5. Crevice corrosion:
Using high content of Cr, Mo metal.
12% Cr steel <17% Cr steel <Austenitic SS< Austenitic 316SS.
6. Stress corrosion:
High Ni content (Ni> 25%-30%) of austenitic Cr-Ni steel.
7. Erosion corrosion:
Ferrite Cr steel <austenite-ferritic steel> austenitic steel.
8. Cavitation corrosion:
Using cavitation resistant material. Such as Hard alloy, Phosphor bronze, Austenitic SS, 12% chrome steel. etc.
How to prevent corrosion problems in slurry pump?
1. Material selection:
Factory experience. Similar applications in other site. Experiecne of pump manufacturers. Appropriate documents etc.
2. Coating technology:
Widely used coating Fusion Bonded Epoxy (FBE) and Polytetrafluoroethylene (PTFE). The effectiveness of the coating is dependents on the type of coating, the preparation of the coating, the application of the coating, the type of corrosion involved, and the type of liquid to which the coating is exposed.
2017年3月14日星期二
8/6FF-AH Horizontal A05 Metal Liner Slurry Pumps in China
8/6FF-AH A05 Horizontal Slurry Pump
Contact Person: Katherine Hou
Contact Person: Katherine Hou
Tel: +86-311-83802338 Fax: +86-311-87162902
Cellphone/ WeChat/ WhatsApp: +86-15028111051
2017年3月9日星期四
Centrifugal Slurry Pump Leak Reason and Solution
The pump works for a long time during the process of running. Which will lead to the leakage due to the corrosion, abnormal process fluctuations and wrong meratial selection etc.
Reason of leakage:
Improper sealing materail selection.
2. The sealing damage because of Empty work, Cavitation or Long time suppress pressure.
3. Lubrication falure lead to the bearing damage and damage the sealing.
4. Sealing damange caused by the working conditions frequent changes or adjustment.
Protection measures:
1, The pump with a reliable seal (such as double-sided seal).
2, DCS add emergency stop pumping facilities.
3, Add the emergency shut-off valve before the pump.
4, Video surveillance.
5, Combustible gas alarm (or smoke Alarm, flame detectors, etc.).
6, Fire facilities at site.
7, Regular inspection or inspection.
Contact Person: Katherine Hou
katherine@naipump.com
Cellphone/ WeChat/ WhatsApp: +86-15028111051
Reason of leakage:
Improper sealing materail selection.
2. The sealing damage because of Empty work, Cavitation or Long time suppress pressure.
3. Lubrication falure lead to the bearing damage and damage the sealing.
4. Sealing damange caused by the working conditions frequent changes or adjustment.
Protection measures:
1, The pump with a reliable seal (such as double-sided seal).
2, DCS add emergency stop pumping facilities.
3, Add the emergency shut-off valve before the pump.
4, Video surveillance.
5, Combustible gas alarm (or smoke Alarm, flame detectors, etc.).
6, Fire facilities at site.
7, Regular inspection or inspection.
Contact Person: Katherine Hou
katherine@naipump.com
Cellphone/ WeChat/ WhatsApp: +86-15028111051
订阅:
博文 (Atom)